Product questions? We’re happy to help! Call +1 770 497-9292 or email shop@murrinc.com

Product Comparison for 2 products

 Forward
Article
Technical Data
Cable length:
Side 1
Tightening torque:
Mounting method:
Coating contact:
Family construction form:
Thread:
Coding:
Material contact:
Material:
No. of poles:
Width across flats:
Degree of protection (EN IEC 60529):
Electrical data | Supply
Operating voltage AC max.:
Operating voltage DC max.:
Current operating per contact max.:
Diagnostics
Status indication LED:
Installation | Connection
Mounting set:
Mating cycles min.:
Device protection | Electrical
Additional condition protection degree:
Pollution Degree:
Insulation resistance min.:
Mechanical data | Material data
Coating locking:
Coating of fitting:
Locking material:
Material screw connection:
Mechanical data | Mounting data
Mounting method:
Environmental characteristics | Climatic
Operating temperature min.:
Operating temperature max.:
Additional condition temperature range:
Important installation notes
Note on strain relief:
Note on bending radius:
Cable data
General data | Cable
Cable identification:
Jacket Color:
Type of Certificate:
Structure | Cable
Amount stranding:
Stranding:
wire arrangement:
Mechanical data | Cable
Material jacket:
Outer-diameter (jacket):
Tolerance outer diameter (sheath):
Material wire insulation:
Amount wires:
Outer diameter insulation :
Outer diameter tolerance core insulation:
Amount strands (wire):
Diameter of single wires:
Conductor crosssection (wire):
Material conductor wire:
Conductor type (wire):
Electrical data | Cable
Nominal voltage AC max.:
Current load capacity (standard):
Current load capacity min. wire:
Electrical resistance line constant wire:
AC withstand voltage (wire - wire):
Power frequency withstand voltage (wire - jacket):
Temperature range | Cable
Min. operating temperature (static):
Max. operating temperature (fixed):
Operating temperature min. (dynamic):
Operating temperature max. (dynamic):
Resistances | Cable
Hydrolysis resistance:
Ozone resistance:
Seewater resistance:
Acid and alkali resistance:
UV resistance:
Flame resistance:
chemical resistance:
Gasoline resistance:
Oil resistance:
Installation | Cable
Bending radius (dynamic):
Travel speed (C-track):
Classifications
ECLASS-6.0:
ECLASS-6.1:
ECLASS-7.0:
ECLASS-8.0:
ECLASS-9.0:
ECLASS-10.1:
ECLASS-11.1:
ECLASS-12.0:
ETIM-5.0:
Commercial data
customs tariff number:
GTIN:
Packaging unit:
Approvals
Certificates
Certificate
Certificate
Certificate
Move
M8 male 0° with cable M8 male 0° with cable
PUR 5x0.25 bk UL 7,5m
Weight: 0.107 kg
Art.No.: 7000-08901-6950750

US Call for Availability
EU Available
Move
M8 male 0° with cable M8 male 0° with cable
PUR 5x0.25 bk UL 10m
Weight: 0.13 kg
Art.No.: 7000-08901-6951000

US Available
EU Available
7,5 m
10 m
0,4 Nm
0,4 Nm
inserted, screwed
inserted, screwed
gold plated
gold plated
M8
M8
M8 x 1
M8 x 1
B
B
Copper alloy
Copper alloy
TPU
TPU
5
5
SW9
SW9
IP67
IP67
30 V
30 V
30 V
30 V
3 A
3 A
no
no
M8 x 1
M8 x 1
100
100
inserted, screwed
inserted, screwed
3/2
3/2
100 MΩ
100 MΩ
Nickeled
Nickeled
nickel plated
nickel plated
Zinc die-casting
Zinc die-casting
Zinc die-casting
Zinc die-casting
inserted, screwed, Shaking protection
inserted, screwed, Shaking protection
-30 °C
-30 °C
80 °C
80 °C
depending on cable quality
depending on cable quality
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
695
695
black
black
-
-
1
1
5 wires twisted
5 wires twisted
brown, white, black, blue, gray
brown, white, black, blue, gray
PUR
PUR
4,7 mm
4,7 mm
± 5 %
± 5 %
PP
PP
5
5
1,2 mm
1,2 mm
± 5 %
± 5 %
32
32
0,1 mm
0,1 mm
0,25 mm²
0,25 mm²
Stranded copper wire, bare
Stranded copper wire, bare
strand class 6
strand class 6
300 V
300 V
to DIN VDE 0298-4
to DIN VDE 0298-4
4,8 A
4,8 A
58 Ω/km @ 20 °C
58 Ω/km @ 20 °C
3 kV @ 60 s
3 kV @ 60 s
3 kV @ 60 s
3 kV @ 60 s
-25 °C
-25 °C
80 °C
80 °C
-10 °C
-10 °C
80 °C
80 °C
-
-
-
-
-
-
-
-
-
-
UL 1581 § 1090 | IEC 60332-2-2 | UL 1581 § 1100 FT2
UL 1581 § 1090 | IEC 60332-2-2 | UL 1581 § 1100 FT2
Good, application-related testing
Good, application-related testing
Good, application-related testing
Good, application-related testing
DIN EN 60811-404 | Good, application-related testing
DIN EN 60811-404 | Good, application-related testing
7,5 x Outer diameter
7,5 x Outer diameter
5 Mio. @ 25 °C
5 Mio. @ 25 °C
27279218
27279218
27279218
-
27279218
27279218
27279218
27279218
27060311
27060311
27060311
27060311
27060311
27060311
27060311
27060311
EC001855
EC001855
85444290
85444290
4048879731713
4048879731720
1
1
* Shipping and Local Tax charges may apply